IGU Technical Data

Ray-Bar fire rated insulated glass units (IGUs) pair a fire rated lite with a second lite of glass as specified, separated by an air space and sealed at the perimeter. The data sheets below cover fire ratings, maximum visible exposed area limits, testing standards and available options for FireLite, WireLite NT, X-ray lead glass and Pilkington Pyrostop IGUs. It is the responsibility of the customer to verify and confirm fire rating requirements prior to ordering.

FireLite IGU Technical Data Sheet & Sizes
Maximum visible exposed area limits for FireLite IGUs in walls and doors:

  • Walls (3/16" FireLite): up to 3,325 square inches at 20, 45 and 60 minutes, and 2,627 square inches at 90 minutes.
  • Doors (3/16" FireLite-NT or 5/16" FireLite Plus): up to 3,204 square inches at 20, 45 and 60 minutes, 2,034 square inches at 90 minutes, and 100 square inches at 180 minutes.

Standard stock sizes run up to 48" x 96", with testing to UL 9, UL 10C, NFPA 80, NFPA 252, NFPA 257, CAN4 S-104 and CAN4 S-106.

X-Ray IGU Technical Data
Specifications for X-ray shielded IGUs:

  • Overall thickness of 1" and up.
  • Nominal lead equivalency of 1/16", with higher equivalencies on request.
  • Weight of 12 lbs per square foot and up.
  • Maximum size of 48" x 96".
  • Fire ratings from 20 to 60 minutes, with up to 3 hours under certain conditions.
  • Passes the UL 10C, UBC 7-2 and UBC 7-4 hose stream standards.

The sheet also covers when impact resistant safety glass is required and how to clean and handle lead glass.

Ray-Bar Fire Rated IGU Technical Data
A side by side overview of Ray-Bar’s two IGU categories. Fire protective IGUs are rated from 20 minutes up to 3 hours, are available in clear ceramic or wired glass, and typically ship in 3 to 5 working days. Fire resistive IGUs are rated from 45 minutes up to 2 hours, suit interior or exterior applications, and protect against radiant and conductive heat (temperature rise per ASTM E-119 and UL 263). The sheet also lists options for each, including impact resistance, X-ray protection, bullet resistance, Low-E, reflective, tinted and 1-way mirror.

3-D IGU Detail
A general 3D detail of a Ray-Bar IGU listing every available glass type, plus performance options and functional options such as electric switchable privacy, internal mini blinds and image projection.

Fire/Ballistic 120 Minute Fire Rated Detail U531 Detail
The UL Design U531 detail for a 120 minute fire rated Pyrostop window in an exterior masonry opening. It allows a maximum exposed area of 3,724 square inches per piece and up to 111" in width or height, tested to ASTM E-119 and UL 263.

Pyrostop 120 Minute Fire Rated and UL Level 3 Bullet Resistant Glass
Data for the 2 7/16" thick Pilkington Pyrostop IGU:

  • Bullet resistant to UL 752 Level 3, resisting handgun threats up to .44 Magnum (3 shots).
  • Rated 60 and 90 minutes in doors and 60, 90 and 120 minutes in walls, with a 3,724 square inch maximum.
  • Acts as a barrier to flame, smoke, and conductive and radiant heat.
  • Estimated STC rating of 46 dB.
  • Suitable for interior or exterior applications.

Fire Rated Lead Lined Vision Frame Detail IGU
Technical data for a fire rated X-ray IGU in a Ray-Bar lead lined vision frame:

  • Fire ratings of 20, 45 and 60 minutes, meeting hose stream and UL 10C positive pressure testing.
  • Impact resistant to ANSI Z97.1 and CPSC 16 CFR 1201 Cat II.
  • 1/16" (1.6 mm) lead equivalent protection.
  • FireLite sizes up to 36" x 89" (3,204 square inches) and WireLite sizes up to 34 3/4" x 92" (3,289 square inches).

Lead shielding must be specified by the project radiation physicist.

Fire Rated X-Ray Glass IGU Details
A detail drawing listing the fire glass and X-ray protective glass combinations available in a single IGU, with ratings from 20 to 180 minutes including temperature rise and hose stream.

FireLite Insulated Glass Units - Detail Rated IGU Side View
A side view detail showing FireLite IGU ratings from 20 to 180 minutes, including temperature rise and hose stream, with fire and smoke protection to UL 9, UL 10, NFPA 80, NFPA 252 and NFPA 257.

FireLite Insulated Glass Units IGU 3D Detail
A 3D cutaway of the FireLite IGU showing its fire glass options and glass options in one view.

WireLite NT IGU Technical Data Sheet & Sizes
Maximum visible exposed area limits for the 1" WireLite NT IGU:

  • Walls at 20 and 45 minutes: up to 1,296 square inches.
  • Wood or metal doors: up to 3,289 square inches at 20 minutes and 1,296 square inches at 45 minutes.
  • Doors at 60 and 90 minutes (non-temperature rise): up to 100 square inches.
  • When glazed with Pemko FG3000 fire tape, larger limits apply, up to 4,608 square inches in walls at 45 minutes.

Standard wire pattern is Diamond and maximum sheet size is 48" x 96". Units are available with Low-E, tinted, reflective, 1-way mirror and X-ray protective glass.

WireLite-NT Insulated Glass Units - Detail Rated IGU Side View
A side view detail showing WireLite NT IGU ratings of 20, 45, 60 and 90 minutes with hose stream. For higher fire ratings, the drawing directs specifiers to FireLite glass products.

WireLite-NT Insulated Glass Units IGU 3D Detail
A 3D cutaway of the WireLite NT IGU with its impact resistance standards and glass options.

Fire Glass Product Submittal Request
Use this form to request specifications, details, installation instructions, samples, handling information or MSDS for your project. Submittals are sent electronically free of charge. Physical copies require a UPS or FedEx account number, and some requests can take up to two weeks.

 

Need Help Specifying a Fire Rated IGU?

Ray-Bar’s team can help you match the right IGU, fire rating and size to your opening. Call 800-444-9729, email sales@fireproofglass.com or submit a fire glass quote request.

 

 

×

In order to submit the form, please fill out all required fields